Стр. 244 - OSRAM_lamp_2014

Упрощенная HTML-версия

5.42
1
2
3
4
5
For fluorescent lamps
For OSRAM DULUX
®
L
Product
Product
4
10
15
18
22
30
38
36
58
18
36
reference
number
6
13
16
6)
20
W
32
W
40
65
24
W
8
W
W
W
W
W
80
W
W
W
Single circuit on 230 V
AC
ST 111 TRY25
5)
4050300854045
X
X
X
X
X
X
X
X
X
X
X
40.3
1
25/400
ST 111 GRP
5)
4050300270166
X
X
X
X
X
X
X
X
X
X
X
40.3
1
1200
ST 111 HT TRY25
3)5)
4050300854021
X
X
X
X
X
X
X
X
X
X
X
40.3
1
400
ST 171 TRY25
4050300854106
X
X
X
1)
X
40.3
3
25/200
ST 171 GRP
4050300422855
X
X
X
1)
X
40.3
3
1200
ST 173 TRY25
4050300854120
X
X
X
X
X
40.3
5
25/200
Series circuit on 230 V
AC
ST 151 TRY25
4050300854083
X
2)
X
2)
X
2)
X
2)
X
2)4)
40.3
2
25/400
ST 151 GRP
4050300012803
X
2)
X
2)
X
2)
X
2)
X
2)4)
40.3
2
1200
ST 172 TRY25
4050300854069
X
2)
X
2)
X
2)4)
40.3
4
25/200
Starters
OSRAM high-quality starters
ST 111 LONGLIFE, ST 151 LONGLIFE,
ST 171 SAFETY, ST 172 SAFETY, ST 173 SAFETY
OSRAM starters ignite every time, reliably and quickly.
And they are gentle on lamps. Each starter is subjected
to strict manufacturing and quality control tests. All
starters have a self-extinguishing insulated casing made
of Makrolon
®
and meet the conditions laid down for
protection class II.
They are equipped with a special compensating capacitor
(foil winding capacitor), are VDE approved and carry the
, and Label marks.
To ensure reliable ignition we recommend that you also
replace the starter when you replace the lamp – except in
the case of DEOS
®
SAFETY.
Switching lifetime for LONGLIFE and DEOS
®
SAFETY:
from ≥10,000 switching operations
to ≥ 60,000 switching operations in inductive mode
20% longer lamp life time for fluorescent lamps
Features and benefits of DEOS
®
ST 171 SAFETY,
DEOS
®
ST 172 SAFETY and DEOS
®
ST 173 SAFETY
DEOS
®
ST 171 SAFETY, DEOS
®
ST 172 SAFETY and
DEOS
®
ST 173 SAFETY are safety starters
DEOS
®
ST 172 SAFETY is a safety starter for series
circuits (tandem circuits)
DEOS
®
ST 171 SAFETY, DEOS
®
ST 172 SAFETY and
DEOS
®
ST 173 SAFETY are designed to operate with
conventional control gear (CCG) and low-loss gear
(LLG)
They reliably disconnect burnt-out or faulty lamps
under inductive or capacitive operating conditions
They are instantly ready for operation when the red
button is pressed in (there must be an audible click)
The automatic cutout circuit protects the choke and
the starter itself
Four times the life of conventional starters
To ensure reliable ignition and operation the
DEOS
®
ST should be replaced after every four
lamp replacements.
Temperature range for reliable cutout: -20°C…+80°C
1) Except L 65 W/…UK 570 mm L 80 W/…
2) Also for single operation on 110/127 V
AC
3) Temperature range –20 °C to +100 °C
4) Not suitable for OSRAM DULUX
®
L and F 24 W in series operation
5) Not suitable for L 70 W
6) 16 W not suitable for series operation